Automatic Packaged Recirculating Coil Tube Generators for unattended operation in specific jurisdictions. Low and High Pressure Steam applications from 75 to 600 BHP
|
|
75 BHP (736 kw) to 600 BHP
(5,885 kw) output.
|
|
|
Standard 15 PSIG (1 BAR) to 500 PSIG
(34.5 BAR) or higher as specified.
|
|
|
Natural Gas and Number 2 Oil.
|
|
|
Up to 85% efficiency with economizers.
|
|
|
ASME, NATIONAL BOARD or as specified. Complies with local code requirements as applicable.
|
|
 |
Compliance with current noise and emissions regulations. |
|
  |
 |
|
 |
|
|
|
|
|
Redesigned combustion air blower for whisper
quiet operation.
|
|
PLC based multiple boiler lead lag control system
with optional DTAM operator, interface c/w percent modulation feedback allowing for each boiler to be operated at its maximum efficiency range at all times.
|
|
|
Multi blade damper on inlet to combustion blower provides lower excess air levels and radiation convection losses.
|
|
|
|
|
A new 4-20 ma Modulating Burner Control provides
more precise control and percentage feedback for
the PLC based Lead Lag control system.
|
|
|
New natural gas control systems provide greater
ease of combustion setup, higher combustion efficiencies and lower NOX levels.
|
|
|
|
|
Redesigned flue gas economizer available with
s/s wrapper sheets.
|
|
|
PLC based flame safeguard control system with optional expanded annunciator.
|
|
Optional pneumatic feedwater control systems.
|
|
 |
|
|
|
|
|
|
Fully modulating burner with 8-1 turndown on
Natural Gas and Number 2 Oil.
|
|
All electrical boxes are oil/dust tight. |
|
|
|
All electrical conduit liquid tight. |
|
|
Switch controls and warning devises located in
a central control panel at the front of the boiler
skid for ease of operation and trouble shooting.
|
|
Separate high voltage side panel. |
|
|
|
Combustion air blower at floor level for ease of inspection and maintenance. |
|
|
All coils have individual monitoring sensors.
|
|
Recirculating pump and combustion blower direct drive. |
|
|
Automatic timer controlled bottom blowdown.
|
|
Most service connections located at common junction point. |
|
|
Manual continuous blowdown or optional
automatic TDS control available.
|
|
|
|
|
Double walled boiler shell preheats combustion air and cools outer casing, thereby minimizing radiation losses. |
|
|
Steam separation drum guarantees 99% plus
dry saturated steam.
|
|
|
|
|
Heavy duty gauge glass assembly |
|
|
Rear door access at floor level without disturbing refractory seal.
|
|
Fuel to steam efficiencies up to 85% with heat recovery. |
|
  |
 |
|
 |
|
Performance Data, Sizes and Dimensions*
|
|
RATED
BOILER
CAPACITY
B.H.P.
|
EQUIVALENT
EVAPORATION
PPH FROM &
AT 212°F
|
THERMAL
OUTPUT BTU/HR
(XCAL/HR)
X 1000
|
FLUE
OUTLET
CONNECTION
INCHES (mm)
|
APPROXIMATE
FUEL CONSUMPTION
|
DIMENSIONS
INCHES (mm)
|
APPROXIMATE
SHIPPING
WEIGHT
LBS (Kg)
|
|
NATURAL GAS
SCFH
|
#2 FUEL OIL
GPH (Lits/H)
|
L (A)
|
W (B)
|
H (C)
|
|
75 A
|
2,587
|
2,511
(633)
|
12
(305)
|
3,138
|
20
(91)
|
110
(2,794)
|
82
(2,083)
|
96
(2,438)
|
6,000
(2,721)
|
|
100 A
|
3,450
|
3,348
(844)
|
14
(356)
|
4,185
|
25
(114)
|
106
(2,692)
|
82
(2,083)
|
96
(2,438)
|
6,600
(2,994)
|
|
150 A
|
5,175
|
5,021
(1,265)
|
16
(406)
|
6,276
|
38
(173)
|
114
(2,896)
|
82
(2,083)
|
100
(2,540)
|
8,400
(3,810)
|
|
200 A
|
6,900
|
6,695
(1,687)
|
18
(457)
|
8,367
|
50
(227)
|
114
(2,896)
|
82
(2,083)
|
100
(2,540)
|
8,200
(3,727)
|
|
200 B
|
6,900
|
6,695
(1,687)
|
18
(457)
|
8,367
|
50
(227)
|
123
(3,124)
|
92
(2,337)
|
116
(2,946)
|
11,000
(4,990)
|
|
250 B
|
8,625
|
8,369
(2,109)
|
20
(508)
|
9,990
|
63
(286)
|
123
(3,124)
|
92
(2,337)
|
116
(2,946)
|
13,300
(6,033)
|
|
300 B
|
10,350
|
10,043
(2,531)
|
24
(610)
|
12,553
|
63
(286)
|
123
(3,124)
|
92
(2,337)
|
116
(2,946)
|
13,300
(6,033)
|
|
350 B
|
12,075
|
11,717
(2,953)
|
24
(610)
|
14,646
|
75
(341)
|
131
(3,327)
|
92
(2,337)
|
116
(2,946)
|
14,200
(6,441)
|
|
400 B
|
13,800
|
13,391
(3,374)
|
24
(610)
|
16,739
|
100
(455)
|
139
(3,530)
|
92
(2,337)
|
116
(2,946)
|
16,900
(7,666)
|
|
450 B
|
15,525
|
15,065 (3,795)
|
24
(610)
|
18,881
|
112
(511)
|
139
(3,530)
|
92
(2,337)
|
116
(2,946)
|
17,300
(7,846)
|
|
400 C
|
13,800
|
13,391
(3,374)
|
24
(610)
|
16,739
|
100
(455)
|
158
(4,013)
|
116
(2,946)
|
124
(3,150)
|
28,000
(12,954)
|
|
500 C
|
17,250
|
16,738
(4,218)
|
26
(660)
|
20,922
|
125
(568)
|
168
(4,267)
|
116
(2,946)
|
124
(3,150)
|
32,000
(14,515)
|
|
600 C
|
20,700
|
20,086
(5,062)
|
28
(711)
|
25,107
|
150
(682)
|
178
(4,521)
|
116
(2,946)
|
124
(3,150)
|
35,800
(16,239)
|
|
|
* Subject to change without notice. Oil fired available for #2 and diesel oil only.
|
|
 |
 |
|
 |
|