Automatic Packaged Units for Low,
Medium and High Temperature Applications
from 75 to 600 BHP
|
|
Forced Circulation, Multi-Coiled Tube, Forced Draft Fired.
|
|
|
Up to 84%
|
|
|
Multi-orificed by Thermogenics.
|
|
|
Air Atomized by Thermogenics.
|
|
|
Natural Gas and Number 2 Oil
|
|
|
Electric Spark Ignited, Interrupted Gas Pilot.
|
|
|
|
Up to 10 to 1 turndown
|
|
|
Designed to ASME and CSA requirements, and Hydro approved.
|
|
|
Programmed Flame Safeguard Control with Ultra Violet Flame Detection. Individual Coil Temperature Control, Low Water and High Temperature Control Valves.
|
|
|
Up to 250 PSIG
|
|
  |
 |
|
 |
|
|
|
|
|
Redesigned combustion air blower ensures
quiet operation.
|
|
Optional linkageless conrol provies lower turndown rates and more consistent efficiencies across the modulating range.
|
|
|
Redesigned damper blades on combustion blower
provide lover excess air levels.
|
|
|
|
|
4-20 ma Modulation for feed back to PLC based Lead/Lag Control.
|
|
|
Redesigned burner increases efficiency.
|
|
|
•
|
Complete flexibility on burner management systems.
|
|
Solid state coil temperature system with individual temperature readouts and set points.
|
|
 |
|
|
|
|
|
|
Fully modulating burner with 10:1 turndown on
Natural Gas and #2 Oil.
|
|
All electrical boxes are oil/dust tight. |
|
|
|
All electrical conduit liquid tight. |
|
|
Switch controls and warning devises located in
a central control panel at the front of the boiler
skid for ease of operation and trouble shooting.
|
|
Separate high voltage side panel. |
|
|
|
Combustion air blower at floor level for ease of inspection and maintenance. |
|
|
All coils have individual monitoring sensors.
|
|
Recirculating pump and combustion blower direct drive. |
|
|
Quick response to load changes.
|
|
Most service connections located at common junction point. |
|
|
Rapid start up from cold start.
|
|
|
•
|
Long life with minimal maintenance coils designed for 1000 PSIG.
|
|
Double walled boiler shell preheats combustion air and cools outer casing, thereby minimizing radiation losses. |
|
|
Rear door access at floor level without disturbing refractory seal.
|
|
|
|
|
|
  |
 |
|
 |
|
Performance Data, Sizes and Dimensions*
|
|
RATED
BOILER
CAPACITY
B.H.P.
|
THERMAL
OUTPUT BTU/HR (KCAL/HR)
X 1000
|
FLUE
OUTLET
CONNECTION
INCHES (mm)
|
APPROXIMATE
FUEL CONSUMPTION
|
DIMENSIONS IN
INCHES (mm)
|
OPERATING
WATER
CAPACITY
GALS (Lits)
|
APPROXIMATE
SHIPPING
WEIGHT
LBS (Kg)
|
|
NATURAL GAS
SCFH
|
#2 FUEL OIL GPH (Lits/Hr)
|
L
|
W
|
H
|
|
75
|
2,511
(633)
|
12
(305)
|
3,138
|
20 (91)
|
114
(2,896)
|
94 (2,388)
|
87 (2,210)
|
18 (82)
|
5,700 (2,591)
|
|
100
|
3,348
(844)
|
14
(356)
|
4,185
|
25 (114)
|
114
(2,896)
|
94
(2,388)
|
87
(2,210)
|
20
(93)
|
6,300 (2,863)
|
|
150
|
5,021
(1,265)
|
16
(406)
|
6,276
|
38 (173)
|
120 (3,048)
|
94
(2,388)
|
91
(2,311)
|
23 (105)
|
8,100 (3,682)
|
|
200
|
6,696
(1,687)
|
18
(457)
|
8,367
|
50 (227)
|
131 (3,327)
|
100
(2,540)
|
101 (2,566)
|
33 (152)
|
10,700 (4,864)
|
|
250
|
8,369
(2,109)
|
20
(508)
|
9,990
|
63 (286)
|
131
(3,327)
|
100
(2,540)
|
101
(2,566)
|
37 (171)
|
13,000 (5,909)
|
|
300
|
10,043
(2,531)
|
24
(610)
|
12,553
|
63 (286)
|
138 (3,505)
|
100
(2,540)
|
101
(2,566)
|
41 (188)
|
13,900 (6,318)
|
|
350
|
11,717
(2,953)
|
24
(610)
|
14,646
|
75 (341)
|
160 (4,064)
|
102
(2,590)
|
101
(2,566)
|
47 (212)
|
16,600 (7,545)
|
|
400
|
13,391
(3,374)
|
24
(610)
|
16,739
|
100 (455)
|
164 (4,166)
|
124 (3,150)
|
116 (2,947)
|
49 (225)
|
28,100 (12,773)
|
|
500
|
16,738
(4,218)
|
26
(660)
|
20,922
|
125 (568)
|
176 (4,470)
|
126 (3,200)
|
116 (2,947)
|
62 (282)
|
31,600 (14,364)
|
|
600
|
20,086
(5,062)
|
28
(711)
|
25,107
|
150 (682)
|
188 (4,775)
|
126 (3,200)
|
116 (2,947)
|
74 (338)
|
35,400 (16,091)
|
|
|
* Subject to change without notice. Oil fired available for #2 and diesel oil only.
|
|
 |
 |
|
 |
|
*The descriptions and specifications contained in this website are approximate and were in effect at the time.
Thermogenics policy is one of continuous improvement and update. Changes to specific models may occur at anytime without notice or incurring any obligation.
|
 |
 |
 |
Download the PDF version of this page. |
|
|
 |
 |
|
|
|
|